In harmony with nature

Haier. World leader
Haier has been a brand of large home appliances №1 for 10 years in a row

* Every fourth refrigerator and every fifth washing machine in the world sold in 2018 was made by Haier.

* According to Euromonitor International, the percentage of sales of large appliances in 2018.

Maximum Comfort

Our HVAC systems brings you a number of features & benefits to ensure you enjoy all round efficiencies whilst experiencing optimal comfort.

Smart Control

A Wi-Fi connected smart air conditioning system allows you the flexibility and convenience of having complete control of your AC unit from wherever you are.

High Quality

Haier's research centre in China has an impressive 150 laboratories where it is possible to test all products according to all national and international regulations specific to the HVAC sector.

Heat pumps
Commercial split systems
VRF systems
Chiller-fancoil systems
Accessories
Haier. Top selling
Cooling Capacity (kW)
5.00...14.50
Heating Capacity (kW)
5.00...16.00
Working temp. Cooling (°C)
+10...+46
Working temp. Heating (°C)
-25...+35
Compressor type
DC inverter twin rotary
Cooling Capacity (kW)
5.00-14.00
Heating Capacity (kW)
5.00-16.00
Working temp. Cooling (°C)
+10...+48°C
Working temp. Heating (°C)
-25...+35°C
Compressor type
DC inverter twin rotary
Cooling Capacity (kW)
4-10
Heating Capacity (kW)
4-10
Working temp. Cooling (°C)
+10...+48
Working temp. Heating (°C)
-20...35
Compressor type
DC inverter twin rotary
Working temp. Cooling (°C)
-10...+46
Working temp. Heating (°C)
-15...+24
Cooling Capacity (kW)
7.10-16.00
Heating Capacity (kW)
8,5-18
Working temp. Cooling (°C)
-20...+46
Working temp. Heating (°C)
-20...+24
Cooling Capacity (kW)
7.10-16.00
Heating Capacity (kW)
7.80-17.00
Air flow (m³/h)
1250-2250
Cooling Capacity (kW)
7,1-14
Heating Capacity (kW)
7,8-16
Working temp. Cooling (°C)
-15 ... +52
Working temp. Heating (°C)
-20 ... +24
Low ESP Slim Duct 01
Cooling Capacity (kW)
2,5-7,1
Heating Capacity (kW)
3,0-8,0
Working temp. Cooling (°C)
до +46
Working temp. Heating (°C)
до -15
Cooling Capacity (kW)
3,5-7,0
Heating Capacity (kW)
4,2-8,0
Working temp. Cooling (°C)
до +43
Working temp. Heating (°C)
до -25
Cooling Capacity (kW)
4,47 — 4,22
Heating Capacity (kW)
3,74 — 4,02
Air flow (m³/h)
3600/3100/2600
EER (kW)
12,3 — 13,6
Cooling Capacity (kW)
13.40
Heating Capacity (kW)
15.00
Air flow (m³/h)
1850
Cassette R410A
Cooling Capacity (kW)
7,1-14
Heating Capacity (kW)
7,8-16
Working temp. Cooling (°C)
-15 ... +52
Working temp. Heating (°C)
-20 ... +24
Cooling Capacity (kW)
3,5-7,0
Heating Capacity (kW)
4,2-8,0
Working temp. Cooling (°C)
до +43
Working temp. Heating (°C)
до -25
Cooling Capacity (kW)
2,5-7,1
Heating Capacity (kW)
3,0-8,0
Working temp. Cooling (°C)
up to +46
Working temp. Heating (°C)
up to -15
Cooling Capacity (kW)
7.10-16.00
Heating Capacity (kW)
7.50-17.00
Air flow (m³/h)
1250-2250
Cooling Capacity (kW)
1,54
Heating Capacity (kW)
1,48
Air flow (m³/h)
680/620/500
EER (kW)
5
Cooling Capacity (kW)
2,12 — 2,52
Heating Capacity (kW)
1,99 — 5,33
Air flow (m³/h)
820 — 2050
EER (kW)
6,8 — 15,5
Cooling Capacity (kW)
1,51 — 2,12
Heating Capacity (kW)
1,55 —1,99
Air flow (m³/h)
600 — 1000
EER (kW)
4,9 — 6,8
Cooling Capacity (kW)
1,54 — 5,52
Heating Capacity (kW)
1,48 — 4,98
Air flow (m³/h)
780 — 2500
EER (kW)
5 — 15,5
Cooling Capacity (kW)
25,2-73,5
Heating Capacity (kW)
27,0-82,5
Working temp. Cooling (°C)
-5 ... 50
Working temp. Heating (°C)
-23 ... 21
Cooling Capacity (kW)
25,2-73,5
Heating Capacity (kW)
25,2-73,5
Working temp. Cooling (°C)
-5 ... 52
Working temp. Heating (°C)
-27 ... 21
Cooling Capacity (kW)
22.4-63
Heating Capacity (kW)
25-69
Working temp. Cooling (°C)
-5~50
Working temp. Heating (°C)
-23~21
Cooling Capacity (kW)
8-33,5
Heating Capacity (kW)
9,5-37,5
Working temp. Cooling (°C)
-15 ... 48
Working temp. Heating (°C)
-15 ... 27
Cooling Capacity (kW)
1,5-3,6
Heating Capacity (kW)
1,7-4
Air flow (m³/h)
700-800
Cooling Capacity (kW)
2,2-5,6
Heating Capacity (kW)
2,5-6,3
Air flow (m³/h)
840
Cooling Capacity (kW)
0,52-162
Heating Capacity (kW)
1,7-5
Air flow (m³/h)
1200-1800
Cooling Capacity (kW)
0,52-162
Heating Capacity (kW)
1,7-5
Air flow (m³/h)
1200-1800
Cooling Capacity (kW)
5,6-16
Heating Capacity (kW)
6,3-18
Air flow (m³/h)
1000-2100
Cooling Capacity (kW)
2,2-16
Heating Capacity (kW)
2,5-18
Air flow (m³/h)
1000-2100
Cooling Capacity (kW)
1,5-7,1
Heating Capacity (kW)
1,7-8
Air flow (m³/h)
430-930
Cooling Capacity (kW)
1,5-16
Heating Capacity (kW)
1,7-18
Air flow (m³/h)
630-2000
Cooling Capacity (kW)
25-28
Heating Capacity (kW)
25-31
Air flow (m³/h)
4050
Cooling Capacity (kW)
14-28
Heating Capacity (kW)
8,9-17,8
Air flow (m³/h)
1600-2800
Built-in floor standing AE-MLERA
Cooling Capacity (kW)
2,2-7,1
Heating Capacity (kW)
2,5-8
Air flow (m³/h)
750-950
Console AF-MBERA
Cooling Capacity (kW)
1,5-5,6
Heating Capacity (kW)
1,7-6
Air flow (m³/h)
620-700
Cooling Capacity (kW)
2,8-14
Heating Capacity (kW)
3,2-16
Air flow (m³/h)
820-2110
High wall AS-MNERAB/MNERA
Cooling Capacity (kW)
1,5-9
Heating Capacity (kW)
1,7-10
Air flow (m³/h)
500-1600
High wall AS-MFERAB/MFERA
Cooling Capacity (kW)
1,5-7,1
Heating Capacity (kW)
1,7-8
Air flow (m³/h)
500-1010
High wall with EV1 kit AS-MNERAC/MFERAC
Cooling Capacity (kW)
1,5-9
Heating Capacity (kW)
1.7-10
Air flow (m³/h)
500-1600
Modular chillers
Cooling Capacity (kW)
30-130
Heating Capacity (kW)
33-135
Compressor type
Scroll compressor
Cooling Capacity (kW)
350-1760
Compressor type
Magnetic bearing compressor
Cooling Capacity (kW)
335-2085
Compressor type
Semi-hermetic screw compressor
Cooling Capacity (kW)
440-7034
Compressor type
Magnetic bearing compressor
Cooling Capacity (kW)
2,41-13,2
Heating Capacity (kW)
3,7-22,5
Air flow (m³/h)
340-2380
Cooling Capacity (kW)
2,41-13,2
Heating Capacity (kW)
3,7-22,5
Air flow (m³/h)
340-2380
Cooling Capacity (kW)
2,41-13,2
Heating Capacity (kW)
3,7-22,5
Air flow (m³/h)
340-2380
Cooling Capacity (kW)
3,6-12,6
Heating Capacity (kW)
6-18,9
Air flow (m³/h)
400-2380
Cooling Capacity (kW)
7,2-15,5
Heating Capacity (kW)
7,7-16,3
Cooling Capacity (kW)
7,2-13,5
Heating Capacity (kW)
7,7-14,4
Working temp. Cooling (°C)
+10 … +43
Working temp. Heating (°C)
-7 … +24
Air flow (m³/h)
1300-2090
Cooling Capacity (kW)
10-14
Heating Capacity (kW)
10,4-16
Working temp. Cooling (°C)
+10°С…+43°С
Working temp. Heating (°C)
-7°С…+24°С
Haier built a factory in Egypt

According to Haier, investment in the project began in 2020, and the plant was launched in February 2021. Currently,...

Haier strives to develop high quality air conditioners

Haier, founded in 1984, has been at the forefront of the technological revolution in the Chinese home appliance industry for 36 years.

Why VRF is the future of the air conditioning market?

The basic VRF system is one outdoor unit with one inverter compressor with VRF technology and several indoor units. The inverter compressor...

We are interested in working with design and installation companies as an official, reliable supplier and partner of the HAIER brand